INTELLIGENT METER EM9200 TYPE K/J THERMOMETER

Item#: 1203

$394.90    AU$359.00


Free Shipping Australia Wide


INTELLIGENT METER EM9200 TYPE K/J THERMOMETER

Comments

Intelligent instrument, multi-function, all in one. The device can be used as a professional Humidity/Temp. meter, Anemometer, Light meter & Sound level meter.

  • Thermocouple Thermometer can default to accept type K or type J Temp. probe.
  • Temperature measurement can default the display unit to C or F.
  • Anemometer can default the display unit to m/S, FPM, Km/h, mph, knots.
  • Light meter can default the display unit to LUX or Ft-cd
  • Meter can default auto power off or manual power off.
  • 0.1 degree resolution for temperature measurement.
  • Microcomputer circuit provides intelligent function and high accuracy
  • RS232 PC serial interface

FEATURES

 Intelligent instrument, multi-function, all in one. Optional * Type K thermocouple probe.

 Meter build in Type K/J thermometer. Be plugged with Accessories TP-01, TP-02A. TP-03, TP-04.

optional " plug & play " probe HD-200PRH, HD-200PAL, * Humidity probe, HD-200PRH

HD-200PLX, SL-407 to be used as a professional * Anemometer probe, HD-200PAL

Humidity/Temp. meter, Anemometer, Light meter, * Light probe, HD-200PLX

Sound level meter. * Sound adapter, SL-407

 Thermocouple Thermometer can default to accept * AC to DC 9V adapter.

type K or type J Temp. probe. * RS232 cable, UPCB-02.

 Temperature measurement can default the display unit * USB cable, USB-01

to or . * Data Acquisition software,

 Anemometer can default the display unit to m/S, FPM, SW-U801-WIN.

Km/h, mph, knot. * Carrying case, CA-05A, CA-06.

 Light meter can default the display unit to LUX or Ft-cd.

 Meter can default auto power off or manual power off. ELECTRICAL SPECIFICATIONS (23±5 )

 0.1 degree resolution for temperature measurement.

 Microcomputer circuit provides intelligent function Type K/J Thermometer

and high accuracy.

 LCD with two display, easy readout. Sensor Reso- Range Accuracy

 Records Maximum and Minimum readings with recall. Type lution

Data hold function for freezing the desired value. Type K 0.1 -50.0 to 1300.0 ± ( 0.4 % + 0.8 )

 Build in the input socket for DC 9V power adapter. -50.1 to -199.9 ± ( 0.4 % + 1 )

 RS232 PC serial interface. 0.1 -58.0 to 2372.0 ± ( 0.4 % + 1.5 )

 Few panel buttons, easy operation. -58.1 to -327.8 ± ( 0.4 % + 1.8 )

 Built-in low battery indicator. Type J 0.1 -50.0 to 1100.0 ± ( 0.4 % + 0.8 )

 Heavy duty & compact housing case. -50.1 to -199.9 ± ( 0.4 % + 1 )

 Available for the HVAC applications. 0.1 -58.0 to 2012.0 ± ( 0.4 % + 1.5 )

-58.1 to -327.8 ± ( 0.4 % + 1.8 )

GENERAL SPECIFICATIONS * Accuracy value is specified for the meter only.

Circuit Custom one-chip of microprocessor LSI * Temp. probe ( Type K, TP-01 TP-02A, TP-03. TP-04 ) is the

circuit. optional accessories, refer page 22.

Display * LCD size : 60 mm x 33 mm

 Dual function meter's display. Anemometer ( optional probe, HD-200PAL )

Measurement * Type K/J thermometer ( optional probe ).

 Humidity/Temp. meter ( optional probe ). A. Air velocity

 Anemometer with Temp. ( optional probe ). Measure- Range Resolution Accuracy

Light meter ( optional probe ). ment tion

 Sound level meter ( optional adapter ). m/S 0.4 - 25.0 m/s 0.1 m/s ± (2% + 0.2 m/s)

Temperature Automatic cold junction compensation km/h 1.4 - 90.0 km/h 0.1 km/h ± (2% + 0.8 km/h)

Compensation both type K/J thermometer mph 0.9 - 55.9 mile/h 0.1 mile/h ± (2% + 0.4 mile/h)

 Type K/J Temp. knot 0.8 - 48.6 knots 0.1 knots ± (2% + 0.4 knots)

Linear Linear Compensation for the full range. FPM 80 - 4930 ft/min 1 ft/min ± (2%+40 ft/min.)

Compensation Note: m/S - meters per second km/h - kilometers per hour

 Type K/J Temp. FPM - feet/per minute knot - nautical miles per hour

Input Socket Standard 2 pin thermocouple socket. mph - miles per hour (international knot)

 Type K/J Temp.

Over Indication Show " ". B. Temperature

Data Hold Freeze the display reading. Measuring Range 0 to 50 /32 to 122

Memory Recall Maximum & Minimum value. Resolution 0.1 /0.1

Sampling Time Approx. 1 second. Accuracy ± 0.8 /1.5

of display

Power off Auto shut off to save battery life or Humidity/Temp. meter ( optional probe, HD-200PRH )

manual off by push button.

Data Output RS 232 PC serial interface. A. Humidity

Operating 0 to 50 . Measuring Range 0 % to 95 % R.H.

Temperature Resolution 0.1 % R.H.

Operating Less than 80% R.H. Accuracy 70% RH ± (3% reading + 1% RH).

Humidity < 70% RH ± 3% RH.

Power Supply 006P DC 9V battery

( Alkaline or Heavy duty type ). B. Temperature

DC 9V adapter input. Measuring Range 0 to 50 /32 to 122

 AC/DC power adapter is optional. Resolution 0.1 /0.1

Power Current Type K/J thermometer : Accuracy ± 0.8 /1.5

Approx. DC 6 mA

Humidity, Anemometer, Light meter : Light meter ( optional probe, HD-200PLX )

Approx. DC 10 mA

Weight 256 g/0.56 LB, main instrument. Measuring Range LUX 0 to 20,000 LUX.

Dimension 180 x 72 x 32 mm Ft-cd 0 to 2,000 Ft-cd

 meter 7.1 x 2.8 x 1.3 inch Resolution LUX 1 LUX

Accessories Instruction manual.................. 1 PC Ft-cd 0.1 Ft-cd

Included Carrying case..........................1 PC Accuracy ± ( 5% rdg ± 8 dgt )

Note: Ft-cd : Feet candle